Contact Lens & Anterior Eye
Volume 33, Issue 3 , Pages 112-118, June 2010

The use of video-keratoscopy in predicting contact lens parameters for keratoconic fitting

Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Ave. West, Waterloo, Ontario N2L 3G1, Canada

published online 04 February 2010.

Abstract 

Purpose

The purpose of this report is to demonstrate the use the video-keratoscope in determining the type and size of the cone in keratoconus and PMD patients and the final back optic zone diameter (BOZD) and total lens diameter (LD).

Methods

A retrospective review of one hundred clinical records including topographic maps, of keratoconic patients (randomly selected) was performed. Cone diameter and type and final contact lens base curve and diameter were recorded.

Results

The types or variations of keratoconus were determined with the use of the tangential map to be either: centred or nipple, early oval cones, moderate oval cones, severe cones or pellucid marginal degeneration (PMD). The size of the cone was dependent on the type and the stage of progression of the cone. Inventory sets for keratoconus that had progressively smaller BOZDs as the base curve or back optic zone radius (BOZR) steepened were found to fit best when prescribed for centred or nipple cones. Inventory sets or multicurve sets that had a constant BOZD with a certain lens diameter that did not vary with the BOZR were found to perform better on oval cones. Very large cones, as with PMD benefited from lenses with very large BOZDs.

Conclusions

Matching the size of the BOZD (and in tandem the LD) to the size of the cone as determined with the tangential topographic map may be a useful tool in aiding in contact lens fitting to increase success.

Keywords: Keratoconus, Contact lens parameters, Tangential maps, Oval cone, Nipple or centred cone, Video-keratography

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1367-0484(10)00003-2

doi:10.1016/j.clae.2010.01.002

Contact Lens & Anterior Eye
Volume 33, Issue 3 , Pages 112-118, June 2010