Contact Lens & Anterior Eye
Volume 33, Issue 1 , Pages 30-32, February 2010

Corneal thinning associated with recurrent microbial keratitis resulting from 7-day extended wear of low Dk hydrogel contact lenses: A case report

  • Genís Cardona

      Affiliations

    • Corresponding Author InformationCorresponding author at: Escola Universitària d’Òptica i Optometria de Terrassa, Violinista Vellsolà, 37, 08222 Terrassa, Catalonia, Spain. Tel.: +34 93 739 8774.
  • ,
  • Carlos Luís Saona-Santos

Research Group of Centre Universitari de la Visió, Optics and Optometry Department, Technical University of Catalonia, Spain

published online 09 November 2009.

Abstract 

Case description

Corneal thinning and an increased risk of corneal perforation, resulting from recurrent episodes of microbial keratitis, required a 38-year-old Caucasian female to undergo bilateral corneal grafting. Although strongly advised otherwise, the patient had been a long time user of low oxygen permeability hydrogel contact lenses in a flexible wear regime, with frequent overnight use.

Discussion

Microbial keratitis is a potentially severe contact lens related complication which, if not properly treated, may lead to permanent visual loss. The introduction of silicone-hydrogel materials and daily replacement modalities has not resulted in a significant decrease in the incidence of microbial keratitis, thus suggesting that the condition is mainly dependent on patient hygiene and wearing habits. Non-compliance, which is endemic in contact lens wear, may be combated by increasing patient awareness of the potential risk factors of contact lens misuse. This is accomplished through constant, rigorous information provided by contact lens practitioners.

Keywords: Corneal thinning, Microbial keratitis, Compliance, Low Dk hydrogel contact lens, Extended wear

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1367-0484(09)00130-1

doi:10.1016/j.clae.2009.10.001

Contact Lens & Anterior Eye
Volume 33, Issue 1 , Pages 30-32, February 2010