Contact Lens & Anterior Eye
Volume 33, Issue 1 , Pages 23-26, February 2010

Toric lens orientation and visual acuity in non-standard conditions

Visioncare Research Ltd., Craven House, West Street, Farnham, Surrey GU9 7EN, UK

published online 24 September 2009.

Abstract 

Purpose

To evaluate and compare the effect of gravity and gaze direction on toric lens orientation and visual acuity (VA).

Method

This was a 14 subject, randomised, unmasked, non-dispensing study, relating to the effect of gaze direction and posture on toric lens orientation and VA. Four lens types were assessed: Acuvue™ Oasys® for Astigmatism (AOfA), Purevision® Toric (PVT), Air Optix® for Astigmatism (AOT) and Proclear® Toric (PCT). In the first part of the study, subjects were positioned on their side and once lenses had settled, VA was measured and photographs taken of the lens orientation position. In the second part, the subjects were positioned at a slit-lamp and video-recordings taken as they changed from the primary gaze position to the eight cardinal directions of gaze.

Results

In Part 1, all lenses rotated as a result of change in posture and head position. With subjects in a recumbent position mean rotation ranged from 11.0° with AOfA to 29.1° with PCT. The consequent mean reduction in VA ranged from 0.05logMAR for AOfA to 0.15logMAR for PVT and was significantly worse with PVT and PCT compared with AOfA (P<0.05). In Part 2, lenses tended to show inferio-nasal rotation on upgaze and inferio-nasal rotation on downgaze. The AOfA lenses showed less rotation on inferio-nasal version than each of the other designs (P<0.005). The AOT lenses showed significantly less rotation on superior-temporal version than PVT (P=0.01).

Conclusion

Toric soft contact lens stability in extreme versions and postural positions can affect orientation and VA.

Keywords: Toric contact lens, Rotation, Gaze direction, Visual acuity

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1367-0484(09)00102-7

doi:10.1016/j.clae.2009.08.003

Contact Lens & Anterior Eye
Volume 33, Issue 1 , Pages 23-26, February 2010