Contact Lens & Anterior Eye
Volume 32, Issue 2 , Pages 68-72 , April 2009

Influence of lens material and intra-ocular pressure on the outcome of non-contact tonometry over soft contact lenses

  • Sudi Patel

      Affiliations

    • Practitioner Services, National Services Scotland, NHSScotland, Gyle Square, 1 South Gyle Cres, Edinburgh EH12 9EB, UK
    • Vissum Institute of Ophthalmology, University Miguel Hernandez, Alicante, Spain
    • Corresponding Author InformationCorresponding author at: Practitioner Services, NSS, NHSScotland, Gyle Square, 1 South Gyle Cres, Edinburgh EH12 9EB, UK. Tel.: +44 131 275 6658.
  • ,
  • Graeme Stevenson

      Affiliations

    • Boots Opticians, Glasgow, Scotland

References 

  1. Krieglstein GK, Waller WK, Reimers H, Langham ME. Augeninnendruckmessung auf weichen kontaktlinsen. Graefes Arch Clin Exp Ophthalmol. 1976;199:223–229
  2. Rubenstein JB, Deutsch TA. Pneumatonometry through bandage contact lenses. Arch Ophthalmol. 1985;103:1660–1661
  3. McMonnies CW. Noncontact tonometry through soft contact lenses. Am J Optom Physiol Opt. 1986;63:948–951
  4. Insler MS, Robbins RG. Intraocular pressure by noncontact tonometry with and without soft contact lenses. Arch Ophthalmol. 1987;105:1358–1359
  5. Panek WC, Boothe WA, Lee DA, Zemplenyi E, Pettit TH. Intraocular pressure measurement with the Tono-Pen through soft contact lenses. Am J Ophthalmol. 1990;109:62–65
  6. Scibilia GD, Ehlers WH, Donshik PC. The effects of therapeutic contact lenses on intraocular pressure measurement. CLAOJ. 1996;22:262–265
  7. Patel S, Illahi W. Non-contact tonometry over soft contact lenses: effect of contact lens power on the measurement of intra-ocular pressure. CLAE. 2004;27:33–37
  8. Mark HH. Corneal curvature in applanation tonometry. Am J Ophthalmol. 1973;76:223–224
  9. Friedenwald JS. Contribution to the theory and practice of tonometry. Am J Ophthalmol. 1937;30:985–1024
  10. Wittenberg S, Green MK. The effect of tears on intraocular pressure as measured with the non-contact tonometer. Invest Ophthalmol. 1976;15:139–142
  11. Forbes M, Pico G, Grolman B. A noncontact applanation tonometer. Description and clinical evaluation. Arch Ophthalmol. 1974;91:134–140
  12. Carel RS, Korczyn AD, Rock M, Goya I. Association between ocular pressure and certain health parameters. Ophthalmology (Rochester). 1984;91:311–314
  13. Sorensen PN. The noncontact tonometer: clinical evaluation on normal and diseased eyes. Acta Ophthalmol. 1975;53:513–521
  14. Allen RJ, Dev Borman A, Saleh GM. Applanation tonometry in silicone hydrogel contact lens wearers. CLAE. 2007;30:267–269
  15. Ehlers N, Bransen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. 1975;53:34–43
  16. Wolfs RCW, Klaver CCW, Vingerling JR, Grobee DE, Hofman A, De Jong PTVM. Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol. 1997;123:762–772
  17. Patel S, McLaughlin JM. Effects of central corneal thickness on measurement of intraocular pressure in keratoconus and post-keratoplasty. Ophthal Physiol Opt. 1999;19:236–241
  18. Hamilton KE, Pye DC, Kao L, Pham N. Tran A-Q N. The effect of corneal edema on dynamic contour and Goldmann tonometry. Optom Vis Sci. 2008;85:451–456
  19. Orssengo GJ, Pye DC. Determination of the true intra-ocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61:551–572
  20. Hamilton KE, Pye DC. Young's modulus in normal corneas and the effect on applanation tonometry. Optom Vis Sci. 2008;85:445–450

PII: S1367-0484(08)00153-7

doi: 10.1016/j.clae.2008.08.005

Contact Lens & Anterior Eye
Volume 32, Issue 2 , Pages 68-72 , April 2009