Contact Lens & Anterior Eye
Volume 31, Issue 2 , Pages 65-72, April 2008

An appraisal of the optics of the hydrodiascope

37 The Ridgeway, Tonbridge, Kent TN10 4NJ, United Kingdom

published online 18 January 2008.

Abstract 

The hydrodiascope is a simple optical device that was introduced in 1896 and for the next 20 years, represented a potentially superior alternative to contact shells as an effective means of optical correction in keratoconus. Previous historical accounts of the hydrodiascope have failed to quantify those optical characteristics that are essential to an understanding of its clinical performance.

The results of this study confirm the validity of the inventor's original equations to determine the focal length of the hydrodiascope lens and show that for powers between +25.00 and +40.00D:

The spectacle magnification ranges from 1.49 up to 5.37.

For a reading distance of one third of a metre from the device, there is a substantial increase in accommodative demand of between 2.81 and 13.90D.

A decrease in vertex distance of the hydrodiascope lens from 10 to 9mm, reduces its effective power between 0.90 and 6.79D.

It is evident that the ability of the hydrodiascope to improve visual acuity to a normal level was due to both neutralisation of irregular astigmatism and the considerable spectacle magnification inherent in the system.

The principal disadvantages of the hydrodiascope were its poor cosmetic appearance and the high demand that it placed upon accommodation. It fell into disuse as contemporary blown scleral shells were gradually replaced by ground scleral lenses. The latter ultimately proved to be capable of improving visual acuity significantly in keratoconus without imposing excessive accommodation and offering the aesthetic advantage of being ‘invisible’.

Keywords: Hydrodiascope, Keratoconus, Scleral shell, Scleral contact lens, History

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1367-0484(07)00131-2

doi:10.1016/j.clae.2007.11.006

Contact Lens & Anterior Eye
Volume 31, Issue 2 , Pages 65-72, April 2008