Repeatability and reliability of ocular aberration measurements in contact lens wear

  • Suzanne Efron

      Affiliations

    • Eurolens Research, The University of Manchester, Moffat Building, P.O. Box 88, Manchester M60 1QD, United Kingdom
  • ,
  • Nathan Efron

      Affiliations

    • Institute of Health and Biomedical Innovation, and School of Optometry, Queensland University of Technology, Cnr Musk Avenue & Blamey Street, Kelvin Grove, Queensland 4059, Australia
    • Corresponding Author InformationCorresponding author. Tel.: +617 3138 6401; fax: +617 3319 6974.
  • ,
  • Philip B. Morgan

      Affiliations

    • Eurolens Research, The University of Manchester, Moffat Building, P.O. Box 88, Manchester M60 1QD, United Kingdom

published online 03 December 2007.

Abstract 

Background

To assess repeatability and within- and between-observer reliability when measuring ocular aberrations with and without soft contact lens wear.

Methods

The irx3 aberrometer was used to measure second to tenth radial order aberrations on 13 subjects with and without their habitual soft contact lenses. This was first performed by one observer, who took three separate measurements to determine repeatability. In addition, two observers each took a set of three measurements on two occasions, to determine within- and between-observer reliability. Data were normalized to a constant pupil size for all measurements made on each subject.

Results

There was no difference in repeatability with or without contact lenses for Zernike polynomial numbers 3–20. There was no difference between within- and between-observer relative reliability either with lenses (t=1.9, p=0.07) or without lenses (t=1.1, p=0.29). However, both within-observer and between-observer reliability were worse when lenses were worn (t=3.6, p=0.0009 and t=2.8, p=0.0074, respectively).

Conclusion

The reduction in within- and between-observer reliability when measuring aberrations in contact lens wearers may be due to variability resulting from a variety of factors, such as lens flexure, lens movement, lens decentration and reduced stability of the pre-lens tear film.

Keywords: Aberration, Contact lens, Eye, Reliability, Repeatability

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1367-0484(07)00124-5

doi:10.1016/j.clae.2007.10.004

Contact Lens & Anterior Eye
Volume 31, Issue 2 , Pages 81-88, April 2008