Contact Lens & Anterior Eye
Volume 30, Issue 1 , Pages 29-36, March 2007

Visual performance after overnight orthokeratology

School of Optometry and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia

published online 11 January 2007.

Abstract 

Purpose

To investigate visual performance after overnight orthokeratology in terms of changes from baseline values, regression of the orthokeratology effect over time, and evaluation of the best-corrected vision after treatment. In particular, to evaluate any residual visual deficits over the duration of a day due to the abnormal corneal topography induced by orthokeratology treatment.

Method

One eye of each of six subjects was fitted with custom designed BE orthokeratology lenses (Capricornia, Brisbane, Australia), with the fellow eye acting as a control. Unaided vision, subjective sphero-cylindrical refraction, high contrast high luminance visual acuity, low contrast high luminance visual acuity, high contrast low luminance visual acuity and letter contrast sensitivity were measured at baseline and after one night (Day 1) and eight nights (Day 8) of lens wear. Except for baseline, data were collected after overnight lens wear immediately after lens removal, and again 3, 6 and 9h after lens removal. At each time point throughout the day, the visual performance measures were evaluated with the initial refraction of the day (the 0h refraction) and also using the optimum subjective refraction at each measurement time. This method was used to evaluate the practical visual performance to be expected after orthokeratology treatment and the residual visual deficits arising from any induced corneal changes after correction of defocus.

Results

As expected, orthokeratology lens wear significantly changed unaided vision and refraction from baseline. However, it did not significantly affect visual acuity in different contrast conditions, or contrast sensitivity. The spherical component of refraction was the only parameter to exhibit regression over each day (p=0.021), with more stability demonstrated on Day 8 than Day 1 (p=0.012). There were no statistically significant changes of best-corrected acuity from baseline in the differing contrast and luminance conditions.

Conclusion

Apart from the predicted improvements in unaided vision and reduction of the myopic refractive error, orthokeratology treatment was not found to significantly change any other aspects of visual acuity and contrast sensitivity. All visual performance measures exhibited stability over a 9-h period. Spherical refractive error changed significantly on Day 1 but became stable after a week of treatment. These results indicate that the corneal topography changes induced by orthokeratology do not induce changes in aberrations that are large enough to significantly diminish visual performance.

Keywords: Orthokeratology, Visual acuity, Contrast sensitivity, Myopia

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 30.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1367-0484(06)00159-7

doi:10.1016/j.clae.2006.12.001

Contact Lens & Anterior Eye
Volume 30, Issue 1 , Pages 29-36, March 2007