An investigation into the antimicrobial mechanisms of action of two contact lens biocides using electron microscopy

  • Caroline E. Codling

      Affiliations

    • Welsh School of Pharmacy, Cardiff University, King Edward VII Avenue, Cardiff CF10 3XF, UK
    • Present address: Alimentary Pharmabiotic Centre, Microbiology Department, University College Cork, Cork, Ireland.
  • ,
  • Anthony C. Hann

      Affiliations

    • Cardiff School of Biosciences, Cardiff University, Cardiff, UK
  • ,
  • Jean-Yves Maillard

      Affiliations

    • Welsh School of Pharmacy, Cardiff University, King Edward VII Avenue, Cardiff CF10 3XF, UK
    • Corresponding Author InformationCorresponding author. Tel.: +44 2920 879088; fax: +44 2920 879149.
  • ,
  • A. Denver Russell

      Affiliations

    • Welsh School of Pharmacy, Cardiff University, King Edward VII Avenue, Cardiff CF10 3XF, UK

published online 08 November 2005.

Abstract 

Polyquaternium-1 (PQ-1) and myristamidopropyl dimethylamine (MAPD) are biocides used commercially in a contact lens disinfecting solutions. Electron microscopy was used to provide further evidence on the mechanism(s) of action of these agents against a wide range of ocular pathogens including bacteria, fungi and protozoa. Both PQ-1 and MAPD caused multiple forms of damage to the organisms tested, evidenced by structural alterations, blebbing, leakage and cell destruction. The extent of damage and the selectivity against specific type of microorganisms was consistent with the antimicrobial activity of these agents. Although electron microscopy is a powerful tool, it has its limitations when used to examine the mode of action of biocides. Indeed, there was no evidence of gross structural alteration to Acanthamoeba castellani or Aspergillus fumigatus following treatment.

Keywords: Electron microscopy, Polyquaternium-1, Myristamidopropyl dimethylamine, Contact lens disinfection, Antimicrobial action

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1367-0484(05)00078-0

doi:10.1016/j.clae.2005.08.002

Contact Lens & Anterior Eye
Volume 28, Issue 4 , Pages 163-168, December 2005